Combined Synopsis/Solicitation
Pressure Myograph System - Combined Notice of Intent and Sources Sought Notice
HEALTH AND HUMAN SERVICES, DEPARTMENT OF · NATIONAL INSTITUTES OF HEALTH · NATIONAL INSTITUTES OF HEALTH NHLBI
NAICS 339112PSC 6515Amended
Response deadlineSep 3, 2026
PostedAug 24, 2026
SolicitationPCA-NHLBI-08252
Notice ID02507f69deed4090959f7b208931c689
Notice typeCombined Synopsis/Solicitation
Set-aside
Place of performanceBethesda, MD, 20892
AwardNot posted
Notice description
The National Heart, Lung, and Blood Institute intends to negotiate and award a purchase order on a sole-source basis to DMT-USA Inc., UEI DUDLHUXCKYJ7, under FAR 13.106-1(b)(1). The proposed acquisition is for one complete pressure myograph system for ex vivo physiological assessment of small arteries and other blood vessels obtained from mouse models. The system will support studies of vascular compliance, stiffness, diameter, axial force, pressure, and functional response under near-physiological conditions. The required system must include, at minimum: A pressure myograph chamber capable of mounting vessels ranging from approximately 60 micrometers to at least 1.2 millimeters in diameter. Interchangeable cannulas suitable for the required vessel-size range. A longitudinal force transducer capable of measuring axial vessel force. Integrated inlet and outlet pressure transducers. A microscope with an integrated camera, infrared illumination, and appropriate objectives. Acquisition and analysis software providing real-time vessel-diameter tracking and display of experimental parameters. Necessary pressure regulation, flow measurement, vacuum, calibration, interface, tubing, cabling, computer, and installation components. Delivery, installation, operational verification, and basic user training. The Governments market research and technical assessment identified DMT-USA Inc. as the only source capable of providing an integrated pressure myograph with the required longitudinal force-measurement capability. This capability is essential for applying consistent vessel stretch and producing accurate, reliable, and reproducible vascular-function data. Other systems reviewed did not provide the complete combination of vessel-size flexibility, longitudinal force measurement, integrated pressure transducers, microscopy, and compatible real-time acquisition software required by NHLBI. Delivery, installation, and training will be performed at an NIH facility in Bethesda, Maryland. The anticipated classification is PSC 6515, Medical and Surgical Instruments, Equipment, and Supplies, and NAICS 339112, Surgical and Medical Instrument Manufacturing. This notice is not a request for competitive quotations. However, all responsible sources may submit a quotation and technical capability documentation demonstrating their ability to satisfy every essential requirement. Responses received by [response deadline] will be considered by the Government. A determination not to compete the proposed acquisition based on responses to this notice is solely within the Governments discretion.
Notice and amendment history
- Combined Synopsis/SolicitationPosted Aug 24, 2026 · closes Sep 3, 2026
- Combined Synopsis/Solicitation · LatestPosted Aug 24, 2026 · closes Sep 3, 2026
Attachments
No attachments are currently listed.