Source-cited

The VA is conducting a Sources Sought Notice for market research regarding a laboratory cryostat system for diagnostic applications in Providence, RI. Vendors must detail product specifications meeting specific technical requirements, such as frozen sectioning and temperature control. [1]

Key points

  • System must produce thin, high-quality frozen tissue sections. [1]
  • VA prefers domestically manufactured items when available. [1]

Watch items

  • Responses are due by September 8, 2026. [1]
  • The notice is for market research only; no award is guaranteed. [1]

Sources

  1. Official SAM.gov noticeThe Government will not reimburse costs associated with responding.

Generated from the public notice and source-backed solicitation passages. Confirm important requirements in the cited brief and official documents.

Public-source intelligence

Source-backed opportunity brief

7 citations · 2 sources

The Government will not reimburse costs associated with responding.

Submission

Submission Instructions All responses shall be submitted electronically to: Dewan.Britton@va.gov Subject line: Sources Sought - Cryostat System 36C24126Q0667 7.

Extracted from the official notice and archived solicitation files. Confirm controlling requirements in the source documents.

Notice information

Read full notice text

1. Purpose This is a Sources Sought Notice issued solely for market research purposes. The Department of Veterans Affairs (VA), Regional Procurement Office East, Network Contracting Office 1, is seeking information from vendors capable of providing a laboratory cryostat system that meets the minimum technical requirements described below. This notice does not constitute a solicitation and does not commit the Government to issue a solicitation or make an award. 2. Minimum Requirement - Salient Characteristics The VA requires a cryostat system designed for producing thin, high-quality frozen sections of biological tissue used in histology, Mohs surgery, pathology, and other diagnostic applications. Vendors must be able to provide equipment that meets all of the following salient characteristics: A. Frozen Sectioning Performance Capable of producing thin, consistent, high-quality frozen tissue sections suitable for diagnostic microscopic examination. Must maintain uniform section thickness with minimal artifacts or surface defects. Must include a precision microtome mechanism that provides accurate trimming and sectioning control. B. Temperature Control & Freezing Must maintain a stable, ultra-low-temperature cryochamber for freezing biological tissues. Must provide rapid specimen-freezing capability to support time-sensitive diagnostic workflows. System must support reliable freezing that preserves cellular structures, morphology, and tissue integrity. C. Operational & Workflow Requirements Must include automated specimen retraction or equivalent safety-enhancing functionality. Must include an integrated user interface such as a touchscreen or comparable control platform that enables hands-off operation of key system functions. Must incorporate features to minimize frost accumulation and improve operator ergonomics during routine use. Must support efficient sectioning workflows suitable for environments requiring high throughput. D. Capacity Must include multiple freezing stations that allow preparation and freezing of multiple specimens. Freezing stations must support consistent and repeatable results, enabling streamlined laboratory workflows. E. Safety & Optional Features Must be designed to reduce repetitive motion strain and improve operator safety. Optional availability of built-in surface disinfection technology (such as UV or equivalent) is preferred but not required. F. Warranty Equipment must include a minimum one-year warranty covering parts and labor. 3. Domestic Manufacturing Preference The VA has a preference for domestically manufactured items, when available. Respondents must indicate: Whether the proposed end product is manufactured in the United States. If not, provide the country of origin. 4. Requested Information From Respondents Interested vendors must submit the following: Company name, address, SAM UEI, and point of contact Business size and socioeconomic classification Product specifications demonstrating capability to meet all salient characteristics listed Technical literature describing the proposed equipment Delivery lead time Information on available installation and training services Warranty terms Country where the end product is manufactured Any federal supply schedule or contract vehicles held Past performance providing similar laboratory or diagnostic equipment 5. Place of Performance Providence VA Medical Center 830 Chalkstone Avenue Providence, RI 02908 6. Submission Instructions All responses shall be submitted electronically to: Dewan.Britton@va.gov Subject line: Sources Sought - Cryostat System 36C24126Q0667 7. Disclaimer This notice is for market research purposes only. It is not a solicitation and does not obligate the Government to make an award. No contract will be awarded based solely on responses to this notice. The Government will not reimburse costs associated with responding.

What changed

No field-level changes were detected between related notices.

Notice history

Attachments

Open a filename to view the saved source file. If a saved copy is not available yet, FedRoster will continue to the matching SAM.gov notice.

Back to top ↑