Place of performanceCharleston AFB, SC, 29404, United States
Opportunity summary
Source-cited
The Department of Defense seeks capabilities for repairing Naval Reserve Training Facility B3370 in Charleston AFB, SC, with a dollar magnitude between $1M and $5M. The project involves HVAC replacement to address mold and includes cybersecurity requirements. [2]
Key points
Requirement value is between $1,000,000.00 and $5,000,000.00. [2]
Selection will use tradeoff procedures for Best Value to the Government. [1]
Official SAM.gov noticeDollar magnitude of this requirement is between $1,000,000.00 and $5,000,000.00.
Sources+Sought+-+Repair+Naval+Reserve+Training+Facility+B3370.pdfAll interested Prime contractors who intend to submit a proposal for this solicitation are highly encouraged to submit a capabilities package to the primary point of contact listed below, no later than (NLT) 12:00pm EST on 1 April 2026:
Generated from the public notice and source-backed solicitation passages. Confirm important requirements in the cited brief and official documents.
Public-source intelligence
Source-backed opportunity brief
7 citations · 3 sources
The successful contractors will be selected using tradeoff procedures resulting in the Best Value to the Government.
All interested Prime contractors who intend to submit a proposal for this solicitation are highly encouraged to submit a capabilities package to the primary point of contact listed below, no later than (NLT) 12:00pm EST on 1 April 2026:
Extracted from the official notice and archived solicitation files. Confirm controlling requirements in the source documents.
Notice information
Read full notice text
The 628th Contracting Squadron at Joint Base Charleston (JBC), SC is seeking capabilities packages from potential sources for planning purposes for the Repair Naval Reserve Training Facility B3370 at Joint Base Charleston, South Carolina. This project includes the renovation of the Naval Reserve Building 3370 that is used for reserve training 1-2 weekends per month with approximately 250 occupants per weekend. Daily occupancy is about 25 people on a normal usage, and the weekends have high occupancy. The project scope is to replace the HVAC equipment in attempts to eliminate the recent mold growth inside the facility and incidental related work. The humid air has caused the need for temporary de-humidifiers and mold cleanup within the facility. The building currently has numerous HVAC roof top units (RTUs), and the climate control is not working to reduce the high humidity inside the building. A new HVAC system will be designed and any mold or water damaged areas removed, and finishes restored, such as re-painting or replacing ceiling tiles. Cybersecurity is also required for this project Renovation. The renovation shall include providing new HVAC units on the roof and providing any electrical equipment needed to support the new HVAC system, as well as providing duct smoke detectors. A HAZMAT survey was performed to determine the extent of mold that may need to be abated during demolition and refinishing. A plumbing sewer line needs repair at the latrines, to replace it with positive drainage to the existing sewer pump. Dollar magnitude of this requirement is between $1,000,000.00 and $5,000,000.00. The NAICS Code assigned to this acquisition is 2362200 - Commercial and Institutional Building Construction with a Size Standard of $45,000,000.00
What changed
Mar 18, 2026 · 2 fields changed
TitleRepair Natural Resources Facility B3370Repair Naval Reserve Training Facility B3370DescriptionThe 628th Contracting Squadron at Joint Base Charleston (JBC), SC is seeking capabilities packages from potential sources for planning purposes for the Repair Natural Resources Facility B3370 at Joint Base Charleston, South Carolina. This project includes the renovation of the Naval Reserve Building 3370 that is used for reserve training 1-2 weekends per month with approximately 250 occupants per weekend. Daily occupancy is about 25 people on a normal usage, and the weekends have high occupancy. The project scope is to replace the HVAC equipment in attempts to eliminate the recent mold growth inside the facility and incidental related work. The humid air has caused the need for temporary de-humidifiers and mold cleanup within the facility. The building currently has numerous HVAC roof top units (RTUs), and the climate control is not working to reduce the high humidity inside the building. A new HVAC system will be designed and any mold or water damaged areas removed, and finishes restored, such as re-painting or replacing ceiling tiles. Cybersecurity is also required for this project Renovation. The renovation shall include providing new HVAC units on the roof and providing any electrical equipment needed to support the new HVAC system, as well as providing duct smoke detectors. A HAZMAT survey was performed to determine the extent of mold that may need to be abated during demolition and refinishing. A plumbing sewer line needs repair at the latrines, to replace it with positive drainage to the existing sewer pump. Dollar magnitude of this requirement is between $1,000,000.00 and $5,000,000.00. The NAICS Code assigned to this acquisition is 2362200 - Commercial and Institutional Building Construction with a Size Standard of $45,000,000.00The 628th Contracting Squadron at Joint Base Charleston (JBC), SC is seeking capabilities packages from potential sources for planning purposes for the Repair Naval Reserve Training Facility B3370 at Joint Base Charleston, South Carolina. This project includes the renovation of the Naval Reserve Building 3370 that is used for reserve training 1-2 weekends per month with approximately 250 occupants per weekend. Daily occupancy is about 25 people on a normal usage, and the weekends have high occupancy. The project scope is to replace the HVAC equipment in attempts to eliminate the recent mold growth inside the facility and incidental related work. The humid air has caused the need for temporary de-humidifiers and mold cleanup within the facility. The building currently has numerous HVAC roof top units (RTUs), and the climate control is not working to reduce the high humidity inside the building. A new HVAC system will be designed and any mold or water damaged areas removed, and finishes restored, such as re-painting or replacing ceiling tiles. Cybersecurity is also required for this project Renovation. The renovation shall include providing new HVAC units on the roof and providing any electrical equipment needed to support the new HVAC system, as well as providing duct smoke detectors. A HAZMAT survey was performed to determine the extent of mold that may need to be abated during demolition and refinishing. A plumbing sewer line needs repair at the latrines, to replace it with positive drainage to the existing sewer pump. Dollar magnitude of this requirement is between $1,000,000.00 and $5,000,000.00. The NAICS Code assigned to this acquisition is 2362200 - Commercial and Institutional Building Construction with a Size Standard of $45,000,000.00