Amendment 1 to 7 Ultrasonic Flowmeters

COMMERCE, DEPARTMENT OF · NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY · DEPT OF COMMERCE NIST

NAICS 334516PSC 6640Amended
Response deadlineSep 4, 2026
PostedAug 28, 2026
Solicitation1333ND26QNB610465
Notice IDc57fd080570247528e4049abe26cec79
Notice typeCombined Synopsis/Solicitation
Set-aside
Place of performanceGaithersburg, MD, 20899
AwardNot posted

Notice description

Amendment 1to RFQ 1333ND26QNB610465 Clarification questions: Vendor Question 1: Could you please confirm the solids content (TSS) of the water? If this is clean water, with less than 2% TSS, please let us know so we can determine the appropriate unit for the application. NIST Response: This water is moderately clean, not a slurry (2% TSS is closer to wastewater) but not filtered Vendor Question 2: The factory has confirmed that no software is required to configure the meter, as very few ultrasonic meters require software for configuration. NIST Response: PC-based data logging is a nice-to-have but not a necessity. Vendor Question 3: (clarification on the following process conditions for the primary and secondary cooling systems) Operating temperature of the process fluid (or pipe surface temperature) at the measurement points, for both the primary and secondary cooling loops. This determines whether standard or high-temperature transducers are required. NIST Response: No higher than 114 degrees Fahrenheit. Vendor Question 4: (clarification on the following process conditions for the primary and secondary cooling systems) Operating pressure of the cooling water at the measurement points (primary and secondary). NIST Response: No higher than 10 psia. Vendor Question 5: (clarification on the following process conditions for the primary and secondary cooling systems) Confirmation of the process fluid — the SOW references cooling water; please confirm it is treated water with no significant entrained solids or aeration that could affect ultrasonic signal transmission. NIST Response: Primary – Heavy water, purified. Secondary - Water with minimal solids. Some algae to be expected but not significant. As defined in the attached Combined Synopsis Solicitation, Statement of Work and RFO Provisions and Clauses.

Notice and amendment history

Attachments and source files

SAM.gov blocks anonymous API download links. Each filename opens the official notice, where SAM.gov provides the authorized file download.